Cisco Switch Catalyst 2960
Арт. WS-C2960-24-S (USED)
79 $
Model: WS-C2960-24-S Cisco 2960 Switch
Dimensions (H x W x D): 1.73 x 17.7 x 9.52 in. (4.4 x 45 x 24.2 cm)
Operating Temperature: 32° to 104°F (0° to 40°C)
Warranty: Limited lifetime warranty
Performance: 16-Gbps switching fabric (Catalyst 2960PD-8TT-L , Catalyst 2960-8TC-L, Catalyst 2960-24TT-L, Catalyst 2960-24TC-L, Catalyst 2960-24LT-L, Catalyst 2960-24PC-L, Catalyst 2960- 48PST-L, Catalyst 2960-48TT-L, Catalyst 2960-48TC-L) _ 32-Gbps switching fabric (Catalyst 2960G-8TC-L, Catalyst 2960G-24TC-L, Catalyst 2960G48TC-L) _ Forwarding rate based on 64-byte packets: 3.6 mpps _ 64 MB DRAM _ 32 MB flash memory _ Configurable up to 8000 MAC addresses _ Configurable up to 255 Internet Group Management Protocol (IGMP) groups _ Configurable maximum transmission unit (MTU) of up to 9000 bytes, with a maximum Ethernet frame size of 9018 bytes (jumbo frames) for bridging on Gigabit Ethernet ports and up to 1998 bytes for bridging of Multiprotocol Label Switching (MPLS) tagged frames on both 10/100 and 10/100/1000 ports
Weight: 8 lb (3.6 kg)
AC Input Voltage: 100 to 240 VAC, autoranging
AC Input Frequency: 47-63 Hz
AC Input Surge Current: 50A maximum, one cycle (-48V power included)
Rack Height: 2RU
Non-Operating Temperature: -40° to 158°F (-40° to 70°C)
Power rating: 0.05 kVA
Acoustic noise: _ ISO 7779: Bystander position operating to an ambient temperature of 25°C _ 0 dBa (no fan)
Safety Certifications: _ UL 60950-1, First Edition _ CUL to CAN/CSA 22.2 No. 60950-1, First Edition _ TUV/GS to EN 60950-1, First Edition _ CB to IEC 60950-1 with all country deviations _ AS/NZS 60950-1, First Edition _ CE Marking _ NOM (through partners and distributors)
Indicators: Per-port status: Link integrity, disabled, activity, speed, full duplex _ System status: System, RPS, link status, link duplex, link speed
Environmental: Reduction of Hazardous Substances (ROHS) 5
Wall Mounting: No
AC Input Current: 3A (110V) 2A (230V)
AC-IP Maximum InLine Power: 360W
Weight (Fully Configured): 25 lb (11.4 kg)
Noise Level (Min/Max): 44 dBA for normal operating temperature (<90°F/32.2°C) 53 dBA (@ maximum fan speed)
Mean time between failures (MTBF): 429,847 hours
Telco: Common Language Equipment Identifier (CLEI) code
Power connectors: Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 675. The connectors are located at the back of the switch. _ Note: The Catalyst 2960-8TC-L and Catalyst 2960G-8TC-L do not have RPS ports. _ Internal power supply connector is an autoranging unit. that supports input voltages between 100 and 240VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. _ Cisco RPS connector: _ Offers connection for an optional Cisco RPS 2300 (model PWR-RPS2300) that uses AC input and supplies DC output to the switch. Only the Cisco RPS 2300 should be attached to the redundant-power-system receptacle. _ Offers a 2300W redundant power system that supports up to 6 external network devices and provides power to 2 failed devices at a time. _ Automatically senses when the internal power supply of a connected device fails and provides power to the failed device, preventing loss of network traffic.
Connectors and cabling: _ 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling _ 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling _ 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling _ 1000BASE-T Small Form-Factor Pluggable (SFP)-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling _ 1000BASE-SX, -LX/LH, -ZX, -BX and CWDM SFP-based ports: LC fiber connectors (single/multimode fiber) _ 100BASE-LX, -BX, -FX: LC fiber connectors (single/multimode fiber)
Environmental ranges N: Normal Operating Conditions: _ -5_C to +45_C, up to 5,000 feet (1500 m) _ -5_C to +40_C, up to 10,000 feet (3000 m) _ -5_C to +35_C, up to 13,000 feet (4000 m) Short-Term* Exceptional Operating Conditions: _ -5_C to +55_C, at sea level _ -5_C to +50_C, up to 5,000 feet (1500 m) _ -5_C to +45_C, up to 10,000 feet (3000 m) _ -5’C to +40’C, up to 13,000 feet (4000 m) * Not more than the following in a 1-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences. For the Catalyst 2960G-8TC-L, reduce the high range temperature by 5°C
AC input voltage and current: 100 to 240 VAC (autoranging), 1.3 to 0.8 A, 50-60 Hz
DC input voltages (RPS input): (No RPS input for Cisco Catalyst 2960PD-8TT-L , Catalyst 2960-8TC-L, and Catalyst 2960G-8TC-L)
Electromagnetic Compatibility Certifications: FCC Part 15 Class A _ EN 55022 Class A (CISPR22) _ EN 55024 (CISPR24) _ AS/NZS CISPR22 Class A _ CE _ CNS13438 Class A _ MIC _ GOST _ China EMC Certifications
Старая цена: 825
Файлы: https://www.router-switch.com/media/upload/product-pdf/guide-to-upgrade-cisco-access-and-backbone-switch.pdf, https://www.router-switch.com/media/upload/product-pdf/selecting-cisco-switches-campus-branch-digital-building.pdf, https://www.router-switch.com/media/upload/product-pdf/cisco-catalyst-2960-2960-sf-2960-s-series-transition-guide.pdf, https://www.router-switch.com/cisco-ws-c2960-24-s-used-datasheet-pdf.html
Dimensions (H x W x D): 1.73 x 17.7 x 9.52 in. (4.4 x 45 x 24.2 cm)
Operating Temperature: 32° to 104°F (0° to 40°C)
Warranty: Limited lifetime warranty
Performance: 16-Gbps switching fabric (Catalyst 2960PD-8TT-L , Catalyst 2960-8TC-L, Catalyst 2960-24TT-L, Catalyst 2960-24TC-L, Catalyst 2960-24LT-L, Catalyst 2960-24PC-L, Catalyst 2960- 48PST-L, Catalyst 2960-48TT-L, Catalyst 2960-48TC-L) _ 32-Gbps switching fabric (Catalyst 2960G-8TC-L, Catalyst 2960G-24TC-L, Catalyst 2960G48TC-L) _ Forwarding rate based on 64-byte packets: 3.6 mpps _ 64 MB DRAM _ 32 MB flash memory _ Configurable up to 8000 MAC addresses _ Configurable up to 255 Internet Group Management Protocol (IGMP) groups _ Configurable maximum transmission unit (MTU) of up to 9000 bytes, with a maximum Ethernet frame size of 9018 bytes (jumbo frames) for bridging on Gigabit Ethernet ports and up to 1998 bytes for bridging of Multiprotocol Label Switching (MPLS) tagged frames on both 10/100 and 10/100/1000 ports
Weight: 8 lb (3.6 kg)
AC Input Voltage: 100 to 240 VAC, autoranging
AC Input Frequency: 47-63 Hz
AC Input Surge Current: 50A maximum, one cycle (-48V power included)
Rack Height: 2RU
Non-Operating Temperature: -40° to 158°F (-40° to 70°C)
Power rating: 0.05 kVA
Acoustic noise: _ ISO 7779: Bystander position operating to an ambient temperature of 25°C _ 0 dBa (no fan)
Safety Certifications: _ UL 60950-1, First Edition _ CUL to CAN/CSA 22.2 No. 60950-1, First Edition _ TUV/GS to EN 60950-1, First Edition _ CB to IEC 60950-1 with all country deviations _ AS/NZS 60950-1, First Edition _ CE Marking _ NOM (through partners and distributors)
Indicators: Per-port status: Link integrity, disabled, activity, speed, full duplex _ System status: System, RPS, link status, link duplex, link speed
Environmental: Reduction of Hazardous Substances (ROHS) 5
Wall Mounting: No
AC Input Current: 3A (110V) 2A (230V)
AC-IP Maximum InLine Power: 360W
Weight (Fully Configured): 25 lb (11.4 kg)
Noise Level (Min/Max): 44 dBA for normal operating temperature (<90°F/32.2°C) 53 dBA (@ maximum fan speed)
Mean time between failures (MTBF): 429,847 hours
Telco: Common Language Equipment Identifier (CLEI) code
Power connectors: Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 675. The connectors are located at the back of the switch. _ Note: The Catalyst 2960-8TC-L and Catalyst 2960G-8TC-L do not have RPS ports. _ Internal power supply connector is an autoranging unit. that supports input voltages between 100 and 240VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet. _ Cisco RPS connector: _ Offers connection for an optional Cisco RPS 2300 (model PWR-RPS2300) that uses AC input and supplies DC output to the switch. Only the Cisco RPS 2300 should be attached to the redundant-power-system receptacle. _ Offers a 2300W redundant power system that supports up to 6 external network devices and provides power to 2 failed devices at a time. _ Automatically senses when the internal power supply of a connected device fails and provides power to the failed device, preventing loss of network traffic.
Connectors and cabling: _ 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling _ 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling _ 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling _ 1000BASE-T Small Form-Factor Pluggable (SFP)-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling _ 1000BASE-SX, -LX/LH, -ZX, -BX and CWDM SFP-based ports: LC fiber connectors (single/multimode fiber) _ 100BASE-LX, -BX, -FX: LC fiber connectors (single/multimode fiber)
Environmental ranges N: Normal Operating Conditions: _ -5_C to +45_C, up to 5,000 feet (1500 m) _ -5_C to +40_C, up to 10,000 feet (3000 m) _ -5_C to +35_C, up to 13,000 feet (4000 m) Short-Term* Exceptional Operating Conditions: _ -5_C to +55_C, at sea level _ -5_C to +50_C, up to 5,000 feet (1500 m) _ -5_C to +45_C, up to 10,000 feet (3000 m) _ -5’C to +40’C, up to 13,000 feet (4000 m) * Not more than the following in a 1-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences. For the Catalyst 2960G-8TC-L, reduce the high range temperature by 5°C
AC input voltage and current: 100 to 240 VAC (autoranging), 1.3 to 0.8 A, 50-60 Hz
DC input voltages (RPS input): (No RPS input for Cisco Catalyst 2960PD-8TT-L , Catalyst 2960-8TC-L, and Catalyst 2960G-8TC-L)
Electromagnetic Compatibility Certifications: FCC Part 15 Class A _ EN 55022 Class A (CISPR22) _ EN 55024 (CISPR24) _ AS/NZS CISPR22 Class A _ CE _ CNS13438 Class A _ MIC _ GOST _ China EMC Certifications
Старая цена: 825
Файлы: https://www.router-switch.com/media/upload/product-pdf/guide-to-upgrade-cisco-access-and-backbone-switch.pdf, https://www.router-switch.com/media/upload/product-pdf/selecting-cisco-switches-campus-branch-digital-building.pdf, https://www.router-switch.com/media/upload/product-pdf/cisco-catalyst-2960-2960-sf-2960-s-series-transition-guide.pdf, https://www.router-switch.com/cisco-ws-c2960-24-s-used-datasheet-pdf.html
The Cisco WS-C2960-24-S (USED) is a reliable and efficient switch designed for small to medium-sized businesses that require a robust LAN solution. As part of the Cisco Catalyst 2960 series, it features 24 10/100 ports and operates under the LAN Lite Image. This switch ensures secure and scalable network management while providing essential networking capabilities.
Quick Spec
| Brand | Cisco |
| Model | WS-C2960-24-S |
| Ports | 24 x 10/100 Ethernet |
| Software | LAN Lite Image |
| Condition | Used |
Product Features
- _ 24 Fast Ethernet ports supporting 10/100 Mbps speeds
- _ LAN Lite software image for streamlined functionality
- _ Robust security features for secure network management
- _ Power-efficient design to reduce energy usage
- _ Enhanced QoS (Quality of Service) for optimization of network traffic
Product Applications
- _ Ideal for small to medium-sized business networks requiring reliable LAN connectivity
- _ Suitable for educational institutions managing classroom networking needs
- _ Perfect for creating secure and efficient networks in retail or branch office environments
Supported Options
| Rack Mount Kit | Cisco RCKMNT-1RU |
| Power Cable | Cisco CAB-AC |
| Console Cable | Cisco CAB-CONSOLE-RJ45 |
Compare to Similar Items
| Model | Differences |
| Cisco WS-C2960-24-TC-L | 24 Fast Ethernet ports, LAN Base Image |
| Cisco WS-C2960G-24TC-L | 24 Gigabit Ethernet ports, LAN Base Image |
| Cisco WS-C2960X-24TS-L | 24 Gigabit Ethernet ports, LAN Base Image, Stackable |
Get more information
For further details about the Cisco WS-C2960-24-S (USED), contact us through Live Chat or email us at [email protected]. Check "Cisco WS-C2960-24-S price" and "WS-C2960-24-S datasheet", buy "Cisco WS-C2960-24-S Switch" with the best price and fast shipping. Free Live Chat support is available.